One day pick the day in the panel
Curtailment by hour, one day
Wind and solar MW that SCED held back each hour of one day: the shape of the energy a flexible load could absorb, which peaks with solar at midday and, on windy nights, overnight. Opens on the latest day.
How it's built
MW wind and solar could have produced (HSL) minus the base point SCED sent them, averaged over each hour: the output SCED held back, for price or for congestion. From the 60-day disclosure where the day has it, otherwise the 2-day estimate.
Across days every 60-day day loaded
Wind and solar offer prices
Share of wind and solar MW offered in each price band, day by day. Tax-credit bids mostly sit between about −$50 and −$25, so the bands below −$20 are where they show up.
How it's built
Share of the MW wind and solar offered each day that was priced in each band, weighted by MW over the day's hours. Tax-credit bids cluster between about −$50 and −$25 with little between −$25 and −$5, so −$20 separates them from shallow negatives. Below −$20 is split into −$250 to −$50, −$50 to −$35 and −$35 to −$20, since most of it sits between −$50 and −$30. Almost nothing is offered at the −$250 floor itself. Uses the 2-day curves where the day has them, otherwise the 60-day curves.
Wind and solar curtailment
How much wind and solar SCED turned away each day, by cause. Congestion (the node price at least $5/MWh below system lambda) is energy stuck behind a transmission constraint, which only a load on the same side could use; oversupply is energy the whole system did not want, available to a load anywhere; operator-directed is ERCOT manually lowering a unit's limit.
How it's built
Energy wind and solar could have produced (HSL) minus what SCED dispatched them to (base point), hour by hour, from the 60-day disclosure unit by unit. Each curtailed hour is priced at the unit's own settlement point and counted as operator-directed where ERCOT's HDL/LDL Manual Override Summary shows an operator lowering the unit's HDL (curtailment up to that reduction, averaged over the hour's runs), as congestion when the node price is at least $5/MWh below system lambda (the energy was worth less where the unit sits, often negative) and as oversupply otherwise (the system as a whole did not want it at the unit's offer). The split is by price, so it says what the energy was worth at the node, not which constraint SCED was managing. Units are matched to nodes through the DAM disclosure; hours with no node price are priced at lambda and counted as unmatched. The price chart groups the curtailed energy by each hour's system lambda (hover for the average curtailed MW over those hours) or by the price at the unit's node, which leaves out operator-directed energy. Recent days with no 60-day data yet show a dashed total estimated from ERCOT's 2-day reports (generation summary base points against the 2-day offer curves' HSL); where both exist the 2-day estimate runs a few percent higher, because the 2-day base points run a little lower.
Units
Each unit's curtailment beside what it earned per MWh. A low realized $/MWh with a high curtailed or congestion share points at a congested node. Sort by any column; click a unit to open it.
How it's built
Realized $/MWh is the unit's revenue over its energy across the loaded 60-day days: energy on the two-settlement basis where it has day-ahead data (the award at the day-ahead price plus the real-time deviation at its node), real-time at its node otherwise, and system lambda where the node price is missing, plus ancillary services. It is left blank under 10 GWh, where a small or new unit's figure is noise. The Unit page has each unit's revenue day by day.
Unused wind and solar, by region and offer price
Wind and solar energy that was available but not dispatched, by where it sat and the price it was offered at: what a flexible load in each region could have taken, and roughly at what price.
How it's built
The same energy as the curtailment chart above: each wind and solar unit's hourly HSL minus its base point, from the 60-day disclosure, unit by unit. Each unit-hour is placed in the unit's zone in ERCOT's Capacity, Demand and Reserves report (Bexar counted as South; newer units the report does not list have no zone), and priced at the unit's submitted offer for the next MW above its base point, at the middle SCED run of the hour (past the last point of its curve, the curve's last price). That is the price it would come back at if the load were there to take it, on the same side of any constraint. Bands run from just above the lower price up to and including the higher one, so an offer at exactly $0 is in "−$5 to $0". HSL is what the operator reports, so a unit that curtails by lowering its HSL hides part of what it could produce. The lambda filter uses each hour's average system lambda.
By region and offer price
Hedge signals
What the scan found ?
Units
Units whose offers track a day-ahead price. “Offers at” is the formula they follow; the implied strike is what that formula suggests the hedge is struck at. Click a unit to open it.
How it's built
Click a column to sort and a unit to open its page, with its fit and bidding history. Share is the slope of offer on the DA price, Intercept its constant. The strike is a range: the high end assumes the intercept is all strike, the low end that the operator also counts a credit of about $30/MWh (roughly the PTC) in its break-even. Floor is the unit's most common offer; DA share is its DAM energy award as a share of its real-time base point energy.
Bidding changes ?
What wind and solar earned from 2019, beside thermal
What wind and solar earned ?
Where the revenue comes from
Since 2019 monthly from January 2019
Across the years
Seven years of wind and solar in four charts: fleet size; energy produced and curtailed; what their MWh earned against the average MWh (the capture rate, below 100% when their output lands in cheap hours or behind congestion); and the share of their output in hours priced at $0/MWh or below, energy a flexible load could have had for next to nothing. The capture rate divides by the hub price weighted by all ERCOT generation, so it compares a wind or solar MWh with what the average generator received; published value factors (Hirth; LBNL) divide by the time-weighted average price instead, so the rates here read lower than those.
How it's built
Every wind and solar unit in ERCOT's 60-day disclosure, hour by hour: monthly from January 2019 from the site's hourly history (built from ERCOT's archive), and daily (and each whole month) since the 60-day data loaded here starts. Fleet size takes the units producing in the month (daily: in the last 30 days) and sums each one's highest hourly HSL over the last 12 months (daily: the day's month so far and the 11 months before). HSL is what SCED saw the unit could produce in that hour's wind or sun, so a single month's best hour runs low in a calm summer (wind's read 2 to 3 GW short every July to September); over a year every unit has had its windy and clear hours. Through November 2019 there is less than a year of data behind each month, drawn dotted. The faint lines are the same units at their installed capacity in ERCOT's Capacity, Demand and Reserves report (one edition, applied to every year, so a repowered unit carries today's rating back); a unit the report doesn't have yet, or no longer has, counts at its 12-month HSL. Energy is telemetered output; curtailed is HSL above base point, the energy SCED held back. A few history months are missing a day or two; their energy is scaled up to the whole month. Capture rate is the price wind or solar earned per MWh (the real-time price at each unit's settlement point, weighted by its output) over the ERCOT hub average price (HB_HUBAVG, real-time) weighted by each hour's ERCOT generation (every unit's output in the 60-day data, storage left out): what the average MWh sold earned at the hub. Below 100% means a wind or solar MWh earns less than the average MWh, from when it produces (more in cheap hours) and where (congestion between its node and the hub). Daily, both are 7-day averages first. The $/MWh switch draws the two sides of the rate instead: the price wind and solar earned and, dashed grey, the average MWh's hub price; the scale is cut at $150/MWh, and the tooltip keeps the true value and the capture rate. In the monthly view the thick flat lines are each calendar year (the current year so far): for the capture rate, the year's revenue per MWh over the whole year divided by all ERCOT generation's hub revenue per MWh over the whole year. The two sides spread their MWh over the months differently, so a year can sit outside its months: in 2021 ERCOT's generation caught more of Winter Storm Uri's prices than solar's did; for the $0 share, the year's output in those hours over all of it. $0 or below is the share of output in hours whose day-ahead price at the unit's node was $0 or less: energy a flexible load at those nodes could have taken for free or been paid to take. The $0-or-below share uses day-ahead prices, which the history carries for every unit and year.