One day set by the day and hour above
Pick an hour
The day's price and generation mix, hour by hour, so you can pick the hour to study below: the cheap midday hours show who keeps running when the price drops, the evening peak who comes on for it. Click an hour; every one-day panel follows it.
Offer curves
The hour's supply curve by technology: how many MW each technology offers at or below each price. Everything left of the price line was willing to run at that price, and the slope at the line is how much more would come on for a small price rise. Wind and solar pile up at negative prices; the thermal blocks that run flat from the left are minimum output, which does not respond to price at all. "Stacked" totals the technologies; "% of offered" rescales each to 100% so a small technology's shape is visible. What “From LSL” means.
How it's built
MW offered at or below each price, averaged over the SCED runs in the hour. The line across the chart marks the cleared price for the hour; the shaded band is its range in that hour. With the 60-day report, "From LSL" draws each technology as the minimum output (LSL) of its online units plus the MW offered above that, so the curve runs flat at LSL and rises with the bids: minimum output runs however low the price goes, and only the MW above it can move by price. "As ERCOT prices it" shows the curves the way SCED sees them, with minimum output at −$20 (−$50 for some units) and the −$250 starts of some submitted curves. The Stacked view shades the LSL block from zero; hover for the split. More on what “From LSL” means.
Why each technology bids this way: coal and gas · wind and solar · batteries →
2-day report: it has no unit limits, so "From LSL" can't be drawn. In Thermal & other, the steps at −$50 and −$20 are minimum output that ERCOT prices there, not bids. Some minimum output is also priced between $0 and about $25, so the curve there shows more than thermal units actually bid. More.
Table view
Who is at the margin
A quick snapshot of this one hour: which technologies would respond first if demand rose or fell a little. Each bar is the MW a technology offers right around the price. On 60-day days it counts only MW SCED could actually move in each 5-minute run: what a unit could reach within its ramp rate, less what it held for reserves. On 2-day days it is the MW offered inside the hour's price range (at least ±$1 around the average), with minimum output taken out. Battery charging that would switch off is drawn below zero: it is demand stepping back, not supply.
How it's built
Marginal supply. Who is offering at the cleared price. On 60-day days with system lambda selected, each SCED run is read on its own: the MW each unit offers within $2 (or 5%) of that run's lambda, plus that interval's highest real-time reserve price, counting only the MW between its LDL plus reserves down and its HDL less reserves up (HDL and LDL are how far its ramp rate reaches in five minutes). Under RTC+B, SCED prices energy and reserves together, so in a scarcity interval lambda sits above the marginal energy offer by about the reserve price a unit gives up; the wider band catches those units. Runs are averaged over the hour. Otherwise (2-day days, or a node price selected): MW each technology offers between the hour's lowest and highest cleared price (at least ±$1 around the average), from the hourly offer curves (it follows the Curve and Price selections), with each unit's minimum output (LSL) taken out, since SCED cannot move a unit below it. Batteries that stop charging as price rises are demand, so they are drawn on the other side of zero. Every share is of all the MW that moves in the window, supply plus charging that stops, so supply above zero and charging below add to 100%; in cheap hours where no supply above LSL is offered near the price, charging is 100%. It shows who stands at the margin, not which unit set each SCED price; with congestion, units can set price locally at prices away from system lambda.
Table view
Marginal generation by price
A snapshot of where bidding sits: the panel above answers "who is at the margin" at the price that cleared, and this one answers it for every price the hour could have cleared at. Each technology's share of the MW offered within a dollar of each price, read off the offer curves; the ticks along the top are the hours' actual system lambdas. Battery charging is drawn below the line as a share of the supply at that price, so it can exceed 100% where little supply is offered. Battery bids move around a lot from hour to hour, so read this as a picture of one hour's or one day's offers rather than a rule. This view reads the offers as submitted: away from the price that cleared, how far each unit could have moved is not known, so ramp rates and reserves are taken out only in Who is at the margin and Marginal generation by settled price.
How it's built
Who would move next if price landed at each level: each technology's share of the MW offered around that price, read off the day's offer curves (the slope of the bid stack). Battery charging bids are demand, so they sit below the line as a share of the supply offered at that price. MW at the −$250 floor (units with no offer curve, mostly nuclear and hydro) are left out, and so is each unit's minimum output (LSL), which SCED cannot move: on days processed before that was done it still shows as a spike at −$20 (−$50 for some units). Ticks along the top mark each hour's system lambda. The same view across every loaded day, by settled price, is in Marginal generation by settled price below.
Curtailment by hour, one day
Wind and solar MW that SCED held back each hour: what they could have produced (HSL) minus the base point it sent. Curtailed MW in a cheap hour is supply a flexible load could have taken. Click an hour to pick it for the page.
How it's built
MW wind and solar could have produced (HSL) minus the base point SCED sent them, averaged over each hour: the output SCED held back, for price or for congestion. From the 60-day disclosure where the day has it, otherwise the 2-day estimate. The same chart as on Renewables, for the day and hour picked on this page.
Thermal dispatch stack
How much thermal output was offered at each price in the hour, and how much of it could actually be used. The stacked areas are the offers of the units online: the flat block on the left is minimum output that runs at any price, and the rest is offered at rising prices. The teal line is the part SCED could reach that hour. A unit's ramp rate limits how far it can move in each five-minute run, and capacity held back for reserves cannot also produce energy, so in a busy hour some offered output is out of reach. Read the price against the teal line: where it meets the system lambda line is close to the hour's actual thermal output (dotted line). Actual output lands a little off that point, mainly because of transmission congestion. SCED dispatches each unit against the price at its own location. When a line is full, units on the congested side see a price below lambda and run less, and units on the uncongested side see a price above lambda and run more.
How it's built
From the 60-day SCED disclosure: every thermal unit online in a SCED run of the hour, its offer curve as SCED dispatched against it (after ERCOT's extension to its limits and any mitigation), held at or above its minimum output (LSL) and at or below its maximum (HSL), averaged over the hour's runs and stacked by how often each unit turns off or by technology. Units that run like peakers (online under 30% of available hours, at most 16 hours a day when on) are their own band, whatever their technology, as on A day in ERCOT. A unit online without an offer curve sits flat at its output that hour. The teal line takes the same offers but holds each unit within the range SCED could use for energy in each run: no higher than the maximum its ramp rate allows in that run (HDL) less the reserves it was carrying, and no lower than the minimum its ramp rate allows (LDL) plus any downward reserves. Where it sits above the stack at low prices, units were still coming down from higher output and could not reach their minimum within the run. Where it sits below at higher prices, units were ramping up or holding reserves. The flat block at the left is the minimum output online, which SCED cannot move at any price; only what rises above it moves with the price. The dashed line is the system floor, the same figure as on A day in ERCOT: every online fossil unit at its LSL plus nuclear at its output, each counted for the share of the hour's SCED runs it was online. It sits on the stack's left edge except when a nuclear plant offers part of its output between -$250 and $0; the note under the chart gives those MW. The vertical line is the hour's real-time system lambda; every unit faces that same price here, so where the teal line meets it is close to the thermal output; the remaining gap comes from congestion, since SCED dispatches each unit against its own node's price. 60-day days only, about two months behind.
Across days: who sets the price, and what gas does to thermal offers
Marginal generation by settled price
What sits at the margin at each price level, pooled over every hour loaded: for the hours that settled near $0, near $20, near $100, which technologies had MW offered right at that price. Read the left edge for cheap hours: that is what a flexible load is bidding against. The one-day version is Marginal generation by price, above.
How it's built
Which resources move when the price moves, across every hour loaded, sorted by that hour's system lambda. Shares are of all the MW whose offer or bid price falls just around lambda: supply, in the 60-day data counting only the MW each unit could move in each SCED run (within its ramp rate, less reserves held), read at that run's own lambda in a band of $2 or 5% plus the interval's reserve price, as in Who is at the margin (the 2-day report has no unit limits, so minimum output stays in there), plus battery charging bids that stop at that price. Supply is drawn above zero and charging below, and the two add to 100%. Smoothed blends the 100 hours nearest each price, so each point rests on the same amount of data. Exact uses only the hours in each $1 band of lambda.
Who sets price, by technology
The most accurate view of who set the price, because it works from settled dispatch rather than offers: a unit is marginal when SCED put it part-way up its own curve, so its offer price was the price at its node. Units are weighted by the room they had left (HDL less reserves, minus base point), the MW that would pick up more load within the five minutes. "At lambda" units set the system price; "below lambda" units sit behind an export constraint and set a cheaper local price, which is where a load could find cheap power; "above lambda" units sit behind an import constraint. Batteries are drawn on their own line.
How it's built
In every SCED run, a unit is on the margin when SCED dispatched it to the interior of its own offer curve: base point strictly inside the ramp-limited range it had that run (LDL to HDL) and not on a vertical step, so the curve's price at the base point is the price SCED saw at the unit's node. A unit climbing at its ramp rate sits at HDL and does not count, and on days processed with ancillary service awards the awards come off that range first (not for combustion turbines, whose check against node prices got worse with it). At system lambda means that implied price is within $2 (or 5%) of the run's system lambda, plus that interval's highest real-time reserve price: the unit is setting the system price. Under RTC+B, SCED prices energy and reserves together, so in a scarcity interval lambda sits above the marginal unit's energy offer by about the reserve price it gives up by producing energy instead; most intervals reserve prices are under $1 and the band is unchanged. Below lambda means it sits behind an export constraint, setting a node price cheaper than the system. Above lambda means it sits behind an import constraint, where the node is dearer. Several units are on the margin in every run, so this is a share of the marginal units, not "the" marginal unit.
Room above base point is the top of the unit's energy range that run (HDL less the reserves it carried, never above HSL) minus base point: the MW a unit can still add at about its own price, which is what would pick up extra load. A unit marginal for a third of an hour's runs counts a third. Generators are shown as a share of the generators' room. Batteries are on their own line because their room runs from wherever they are, charging included, all the way up to HDL less reserves: stopping charging and then discharging, which is real flexibility but would swamp the shares. Marginal units counts unit-hours instead, where batteries are many and small. The lambda filter uses each hour's average system lambda. Regions are the units' zones in ERCOT's Capacity, Demand and Reserves report (Bexar counted as South); newer units the report does not list have no zone. Days processed before the per-unit files carried per-run base points use the hourly mean instead and leave batteries out.
By region
Units most often on the margin away from lambda
How well this checks against node prices
Read below lambda for storage and combustion turbines with caution. When their curve price is more than $5 from the node price, the node is dearer in nearly every case: the unit offered cheaper than its node and still was not dispatched up, so something the disclosure does not show held it back. A test on the 15 days with the most mismatches found that netting ancillary service awards brings coal and gas steam to about 90% within $5 but leaves storage and combustion turbines near 50%, and that ramp limits, ERCOT's SCED1 curve and, for most runs, state of charge do not explain the rest. About a fifth of the remaining gaps fall in 15-minute intervals where lambda moved by more than $5, which the 15-minute node price averages away.
Thermal offers and fuel prices
Do thermal offers follow gas? The top chart tracks, day by day, the price at which a quarter, half and 90% of a technology's MW above minimum output is offered, against the hourly system lambda. Below it are the gas prices at the three hubs and, dividing offers by gas, the heat rate gas units' offers imply: a flat line near a unit's real heat rate means offers are fuel cost; a rising line means margin is being added.
How it's built
Price at which 25%, 50% and 90% of a technology's submitted MW above minimum output (LSL) is offered, averaged over the day's hours. Only units online in each SCED run count, so a quantile can move because of who is committed as well as how they bid: when few combustion turbines run, a handful of units weigh heavily. On Mar 12, 2026, for example, Waha gas was near −$7/MMBtu and Elk Station 1 and Ector County G1 and G2 offered most of their MW at about −$50, which took the turbines' 25% and 50% prices below $0. Minimum output is left out because SCED cannot dispatch below it; days processed before that was done use the whole curves, where the first quantiles sit inside the minimum-output block. A falling median with a steady lambda means units are bidding more of their capacity cheaply. Nuclear submits no curves, and there is no coal price series, so coal has offer prices but no implied heat rate.
Natural gas and implied heat rate
Gas prices at Houston Ship Channel, Waha and Henry Hub, and the heat rate gas units' offers imply against the gas at their own hub.
How it's built
Henry Hub is the daily spot from the EIA. Houston Ship Channel and Waha (West Texas) come from OilPriceAPI under a licence that does not allow republishing their prices, so they are shown as a 7-trading-day average with no download; the heat rate below uses the daily prices. Waha often trades well below the others and at times below $0, which pulls West Texas gas units' offers toward or below $0. Below that is an implied heat rate for combined cycles, combustion turbines and gas steam units. For each unit, the price of the first point on its submitted curve at or above its minimum output (LSL) that is priced above $0, averaged over its online SCED runs that day, is divided by the price of gas at the unit's own hub on the last trading day before it, since gas trades the day before it flows. Starting at LSL leaves out the part of the curve SCED can never dispatch (many curves run from 0 MW at −$250 up to the unit's real price, and the part below LSL is just that line), and starting above $0 skips blocks offered at or below $0, so this is roughly the price a unit asks to move up from its minimum. Each day uses every unit's most recent value from the last 14 days, so the line follows the whole fleet rather than only the units that happened to run, and shows the median across units. Days with fewer than 10 units are left blank. The result is the heat rate (MMBtu per MWh) the offers imply if they were pure fuel cost. A steady implied heat rate with a moving offer price means the offers are tracking gas; a changing one means something else moved (margins, variable costs, the mix of units offering). Each unit's hub, Waha or Houston Ship Channel, comes from the Fleet economics assignment: the hub its own offers follow when they clearly follow one, otherwise its location (West and Panhandle nodes on Waha, everything else on Ship Channel). Units without an assignment use Ship Channel, and Henry Hub stands in when neither hub's prices are loaded. Days when a unit's hub trades at or below $0 give no heat rate for it, so it keeps its last value from the 14 days before.